跳至主要內容
← 返回文獻索引

Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2021 · 系統性回顧(依標題推測)

A systematic review evaluating the clinimetric properties of the Victorian Institute of Sport Assessment (VISA) questionnaires for lower limb tendinopathy shows moderate to high-quality evidence for sufficient reliability, validity and responsiveness-part II

髖與鼠蹊 · 近端腿後肌肌腱病變

中文閱讀摘要

系統性回顧評估下肢肌腱病變VISA問卷,發現其信度、構念效度及反應性具中至高品質證據,但VISA-A測量誤差證據不足。

AI 依來源摘要整理,未經人工逐篇核對。閱讀結論前,請回溯研究族群、方法與限制。

原始摘要

Purpose

The evaluation of measurement properties such as reliability, measurement error, construct validity, and responsiveness provides information on the quality of the scale as a whole, rather than on an item level. We aimed to synthesize the measurement properties referring to reliability, measurement error, construct validity, and responsiveness of the Victorian Institute of Sport Assessment questionnaires (Achilles tendon-VISA-A, greater trochanteric pain syndrome-VISA-G, proximal hamstring tendinopathy-VISA-H, patellar tendon-VISA-P).

Methods

A systematic review was conducted according to Consensus-based Standards for the Selection of Health Measurement Instruments methodology (COSMIN). PubMed, Cochrane, CINAHL, EMBASE, Web of Science, SportsDiscus, grey literature, and reference lists were searched. Studies assessing the measurement properties concerning reliability, validity, and responsiveness of the VISA questionnaires in patients with lower limb tendinopathies were included. Two reviewers assessed the methodological quality of studies assessing reliability, validity, and responsiveness using the COSMIN guidelines and the evidence for these measurement properties. A modified Grading of Recommendations Assessment Development and Evaluation (GRADE) approach was applied to the evidence synthesis.

Results

There is moderate-quality evidence for sufficient VISA-A, VISA-G, and VISA-P reliability. There is moderate-quality evidence for sufficient VISA-G and VISA-P measurement error, and high-quality evidence for sufficient construct validity for all the VISA questionnaires. Furthermore, high-quality evidence exists with regard to VISA-A for sufficient responsiveness in patients with insertional Achilles tendinopathy following conservative interventions.

Conclusions

Sufficient reliability, measurement error, construct validity and responsiveness were found for the VISA questionnaires with variable quality of evidence except for VISA-A which displayed insufficient measurement error.

Level of evidence

IV.

Registration details

Prospero (CRD42018107671); PROSPERO reference-CRD42019126595.

至 Europe PMC 閱讀完整來源 ↗ · 擷取日期 2026-10-19

書目、來源與全文狀態
DOI
10.1007/s00167-021-06557-0
PMID/PMCID
33860806 / PMC8384816
作者
Korakakis V, Whiteley R, Kotsifaki A, Stefanakis M, Sotiralis Y, Thorborg K
首次發表日期
2021-04-16Europe PMC 提供,部分日期可能依年份或月份推定。
卷/期/頁碼或文章編號
29 / 9 / 2765-2788
書目來源與查核日期
Europe PMC · 2026-10-19僅核對書目欄位與來源連結;不代表已評讀研究品質。
全文與授權
來源列有免費全文(查核 2026-10-19),未逐篇測試 PDF 下載。 來源授權標示:cc by。

可回溯引用

Korakakis V, Whiteley R, Kotsifaki A, Stefanakis M, Sotiralis Y, Thorborg K. A systematic review evaluating the clinimetric properties of the Victorian Institute of Sport Assessment (VISA) questionnaires for lower limb tendinopathy shows moderate to high-quality evidence for sufficient reliability, validity and responsiveness-part II. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2021;29(9):2765-2788. PMID: 33860806. PMCID: PMC8384816. doi:10.1007/s00167-021-06557-0

本站供教育與研究參考。單篇摘要、文體標籤與期刊影響係數不等於證據品質或個別病人的診療建議。