Frontiers in sports and active living · 2026 · 系統性回顧+統合分析(依標題推測)
Carbon plates in running shoes biomechanics: a systematic review and meta-analysis
影像・診斷・生物力學 · 跑步生物力學
中文閱讀摘要
統合分析顯示碳板跑鞋相較非碳板鞋,對下肢關節功率與腿剛度無顯著系統性改變,僅踝關節功率呈邊際降低,證據確信度低至中等。
AI 依來源摘要整理,未經人工逐篇核對。閱讀結論前,請回溯研究族群、方法與限制。
原始摘要
Background
Carbon-plated running shoes (CPS) combine compliant foams with embedded carbon-fiber plates to increase longitudinal bending stiffness and potentially improve running economy. However, whether CPS systematically alter running biomechanics compared with non-carbon-plated shoes (NCPS) remains unclear.
Objective
To quantify the biomechanical effects of CPS in healthy adults.
Methods
A systematic review and meta-analysis of crossover trials comparing CPS vs. NCPS was conducted according to PRISMA guidelines (PROSPERO CRD420251058609). Searches were performed in MEDLINE, Scopus, LILACS, and Embase (July 2025). Eligible studies included healthy adults (18-70 years) running in CPS and NCPS. Outcomes were step frequency (steps·min - ¹), leg stiffness (kN·m - ¹), and peak positive joint power (W·kg - ¹) at the metatarsophalangeal (MTP), ankle, knee, and hip. Random-effects models were used to estimate standardized mean differences (SMDs) with 95% confidence intervals (CIs). Certainty of evidence was assessed using GRADE.
Results
Fifteen studies were included. No significant differences were observed between CPS and NCPS for leg stiffness (SMD = -0.12; 95% CI: -0.46 to 0.23; p = 0.44), knee power (SMD = 0.21; 95% CI: -0.10 to 0.52; p = 0.12), hip power (SMD = -0.23; 95% CI: -1.36 to 0.90; p = 0.56), or MTP power (SMD = 0.13; 95% CI: -1.87 to 2.12; p = 0.85). A borderline reduction in ankle power was observed with CPS (SMD = -0.71; 95% CI: -1.42 to 0.00; p = 0.05). Step frequency showed a small, non-significant decrease (SMD = -0.16; 95% CI: -0.32 to 0.01; p = 0.06). Certainty ranged from low to moderate.
Conclusion
CPS do not produce consistent changes in joint power or leg stiffness compared with NCPS. Biomechanical adaptations appear subtle, with possible distal joint effects but no systematic redistribution of lower-limb mechanics.
Systematic review registration
PROSPERO CRD420251058609.
至 Europe PMC 閱讀完整來源 ↗ · 擷取日期 2026-10-19
書目、來源與全文狀態
- DOI
- 10.3389/fspor.2026.1764338
- PMID/PMCID
- 42293993 / PMC13260470
- 作者
- Giachetti Martin S, Kobayashi EN, Amaral Coelho de Azevedo L, Bonini Vieira Campanhã D, Escudeiro de Oliveira D, Baches Jorge P
- 首次發表日期
- 2026-05-29Europe PMC 提供,部分日期可能依年份或月份推定。
- 卷/期/頁碼或文章編號
- 8 / 期未提供 / 1764338
- 書目來源與查核日期
- Europe PMC · 2026-10-19僅核對書目欄位與來源連結;不代表已評讀研究品質。
- 全文與授權
- 來源列有免費全文(查核 2026-10-19),未逐篇測試 PDF 下載。 來源授權標示:cc by。
可回溯引用
Giachetti Martin S, Kobayashi EN, Amaral Coelho de Azevedo L, Bonini Vieira Campanhã D, Escudeiro de Oliveira D, Baches Jorge P. Carbon plates in running shoes biomechanics: a systematic review and meta-analysis. Frontiers in sports and active living. 2026;8:1764338. PMID: 42293993. PMCID: PMC13260470. doi:10.3389/fspor.2026.1764338
本站供教育與研究參考。單篇摘要、文體標籤與期刊影響係數不等於證據品質或個別病人的診療建議。